Electrical cabinet

The electrical cabinet installed in the network areas groups all the electrical devices necessary for the proper functioning of the stopover area and distributes the current to the various equipment (barrier, service terminal, payment terminal, etc…).

Template photo principale equipements 610x450 3

TECHNICAL CHARACTERISTICS OF THE ELECTRICAL CABINET :

FULL LVDP

Electrical features :

  • 30mA protection for : entrance terminal, exit terminal, barrier, payment terminal
  • Rated operating voltage Ue : 440V or 230V
  • Rated impulse withstand voltage Uimp : 4.5 kV
  • Rated current of the assembly (Ina) and of the electrical circuit (Inc)
  • INA 40A
  • INC to be adapted according to the options selected
  • Rated peak current (Ipk)
  • NFN ”C” circuit breakers
  • 6 kA NF EN 60898-1
  • 10 kA NF EN 60947-2
  • Thermal magnetic faults indicated by lights (yellow colour)
  • For copper conductor, connexion capacity: – 25² flexible wire – 35² rigid wire
  • Certified according to NF EN 60898-1
  • Compliant with NF EN 60947-2
  • Frequency allocation (FAT): 50 Hz.
  • Class I Degree of protection against electrical shock
  • Surge protector
  • USB inverter
  • Surge protector circuit breaker
  • Cut-off switch
  • RCBO
  • Barrier RCD

 

Environmental  features :

  • Pollution degree 3
  • Earthing system permissible: TT, TN ou IT
  • Installation type : fixed outdoor installation
  • Degree of protection: IP45
  • Design: cabinet
  • Impact protection: IK08
  • Operating temperature range:-25 to +40°C
  • Hygrometry: 100% at 25°C

 

Mechanical features :

  • Weight: 70 Kg
  • Measurements: H 1400 x L 870 x L 400
  • INOX 316L Qualimarine® certification
  • RAL 9001 (other optional RAL)